07/31/2025 01:57:54.921 7f7fb09582e8 [contrail-analytics-alarm-nodemgr] [ERROR]: Cannot write http_port 8113 to /tmp/contrail-analytics-alarm-nodemgr.0.http_port 07/31/2025 01:57:54.921 7f7fb09582e8 [contrail-analytics-alarm-nodemgr] [ERROR]: Starting Introspect on HTTP Port 8113 07/31/2025 01:57:54.923 7f7fb0956c18 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] NodeStatusUVE: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local process_status = [ << module_id = contrail-analytics-alarm-nodemgr instance_id = 0 state = Non-Functional connection_infos = [ << type = Collector name = Collector server_addrs = [ , ] status = Down description = none to Idle on EvStart >>, ] description = Collector:Collector[none to Idle on EvStart] connection down >>, ] >> 07/31/2025 01:57:54.923 7f7fb0956c18 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] SandeshModuleClientTrace: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local:AnalyticsAlarm:contrail-analytics-alarm-nodemgr:0 client_info = << status = Idle successful_connections = 0 pid = 1 http_port = 8113 start_time = 1753927074923114 collector_name = collector_ip = collector_list = [ 10.0.0.48:8086, ] >> sm_queue_count = 1 max_sm_queue_count = 1 >> 07/31/2025 01:57:57.999 7f7fb0a1e828 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] NodeStatusUVE: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local build_info = {"build-info" : [{"build-version" : "nightly", "build-time" : "2025-07-31 00:51:12.408828", "build-user" : "root", "build-hostname" : "jenkins-build-prepare-sandbox-10082-1.novalocal", "build-id" : "nightly", "build-number" : "nightly.el7"}]} system_cpu_info = << num_socket = 1 num_cpu = 4 num_core_per_socket = 4 num_thread_per_core = 1 >> running_package_version = nightly-nightly.el7 installed_package_version = nightly-nightly.el7 >> 07/31/2025 01:57:58.000 7f7fb0a1e828 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] NodeStatusUVE: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local process_status = [ << module_id = contrail-analytics-alarm-nodemgr instance_id = 0 state = Non-Functional connection_infos = [ << type = Collector name = Collector server_addrs = [ , ] status = Down description = none to Idle on EvStart >>, ] description = Collector:Collector[none to Idle on EvStart] connection down >>, ] >> 07/31/2025 01:57:58.000 7f7fb0a1e828 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] NodeStatusUVE: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local deleted = False process_info = [ << process_name = contrail-alarm-gen process_state = PROCESS_STATE_RUNNING start_count = 1 stop_count = 0 exit_count = 0 last_start_time = 1753927069000000 last_stop_time = last_exit_time = core_file_list = [ ] >>, << process_name = kafka process_state = PROCESS_STATE_RUNNING start_count = 1 stop_count = 0 exit_count = 0 last_start_time = 1753927027000000 last_stop_time = last_exit_time = core_file_list = [ ] >>, << process_name = contrail-analytics-alarm-nodemgr process_state = PROCESS_STATE_RUNNING start_count = 1 stop_count = 0 exit_count = 0 last_start_time = 1753927070000000 last_stop_time = last_exit_time = core_file_list = [ ] >>, ] build_info = {"build-info" : [{"build-version" : "nightly", "build-time" : "2025-07-31 00:51:12.408828", "build-user" : "root", "build-hostname" : "jenkins-build-prepare-sandbox-10082-1.novalocal", "build-id" : "nightly", "build-number" : "nightly.el7"}]} >> 07/31/2025 01:57:58.049 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 01:57:58.950 7f7fb0a1f438 [contrail-analytics-alarm-nodemgr] [ERROR]: SANDESH: [DROP: WrongClientSMState] NodeStatusUVE: data = << name = cn-jenkins-deploy-platform-k8s-manifests-232-1.cluster.local process_status = [ << module_id = contrail-analytics-alarm-nodemgr instance_id = 0 state = Non-Functional connection_infos = [ << type = Collector name = Collector server_addrs = [ 10.0.0.48:8086, ] status = Initializing description = Idle to Connect on EvIdleHoldTimerExpired >>, ] description = Collector:Collector[Idle to Connect on EvIdleHoldTimerExpired] connection down >>, ] >> 07/31/2025 01:58:58.022 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 01:59:58.023 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:00:58.027 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:01:58.041 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:02:58.071 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:03:58.054 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:04:58.060 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:05:58.061 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes' 07/31/2025 02:06:58.064 7f7fb312b9c8 [contrail-analytics-alarm-nodemgr] [ERROR]: Failed to get core files: [Errno 2] No such file or directory: '/var/crashes'